Chiller Units for Machining Coolant Systems Flush

Model NO.: WD-AC/S
Application Fields: Chemical
Application Machine: Combination machine
Certification: ISO, CE
Condition: New
Cooling Capacity: 12rt
Refrigerant Type: R22/R134A/R407c/R410A/R507/R404
Dimensions: 2060*1025*1910mm
Total Weight: 1035kg
Trademark: WINDAY
Transport Package: Plywood Box
Specification: CE, ISO9001
Origin: Shanghai
HS Code: 8418699090
Model NO.: WD-AC/S
Application Fields: Chemical
Application Machine: Combination machine
Certification: ISO, CE
Condition: New
Cooling Capacity: 12rt
Refrigerant Type: R22/R134A/R407c/R410A/R507/R404
Dimensions: 2060*1025*1910mm
Total Weight: 1035kg
Trademark: WINDAY
Transport Package: Plywood Box
Specification: CE, ISO9001
Origin: Shanghai
HS Code: 8418699090

Chiller Units For Machining Coolant Systems Flush
 

Our products as follow:

3kw ~ 3000kw/Outlet temperature:7ºC~ -85ºC/
Air cooled,water cooled,screw type,scroll type,heat pump chiller, modular chiller

 






Chiller Units for Machining Coolant Systems Flush









Chiller Units for Machining Coolant Systems Flush




The Details of the chiller:

1.The Temperature Range:7ºC to -85ºC.  

2.Cooling Capacity Range:

1RT to 1000RT

3.52kw to 3520kw

12010Btu to 12010240Btu

3027.2Kal to 3027200Kal

3. The Refrigerant: R22/R407c/R410a/R404a/R134a/R507c.
4.We can also produce the chiller according to your requirements.
Chiller Units for Machining Coolant Systems Flush






One Parameter of our water chiller:
Air-cooled chiller parameters(output tem 7ºC)

Model  UNIT WD-  
3AC/S 5AC/S 8AC/S 10AC/S 12AC/S 15AC/S 20AC/S 25AC/S 30AC/S 40AC/S
Cooling capacity Btu 30026 49133 87006 98948 111572 140233.2 188684 223145 280466 377367
RT 2.5 4.1 7.2 8.3 9.3 11.7 15.7 18.6 23.4 31.5
Kw 8.8 14.4 25.5 29.0 32.7 41.1 55.3 65.4 82.2 110.6
×10³Kcal/h 7.6 12.4 21.9 25.0 28.1 35.4 47.6 56.3 70.7 95.2
 Total Power KW 3.1 5.2 8.1 9.5 10.9 14.4 19.3 20.5 28.6 38.0
Total Current A 5.7 9.6 14.8 17.3 19.9 26.3 35.3 37.6 52.3 69.5
       Compressor  Qty set 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.00 2.00 2.00
Input power kw 2.6 4.3 7.0 7.9 8.9 12.4 16.6 17.9 24.9 33.3
 Operation Current A 4.6 7.6 12.4 14.0 15.9 22.1 29.6 31.8 44.3 59.2
Condenser Type Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger  
Fans Input power kw 0.19 0.42 0.38 0.84 0.84 0.84 1.14 1.14 1.50 2.52
Input
Current
 
A 0.50 0.85" 1.00 1.70" 1.70 1.70 3.00 3.00 3.84 5.10"
  Evaporator  Type   Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger  
  Freezing water Flow L/min 25 41 73 83 93 118 158 187 235 316
Water pipe connection mm 25" 25 32 32 32 40 40" 50 50 65"
Freezing Water Pump Type  High efficiency, low noise  
Input Power Kw 0.37 0.55 0.75 0.75 1.10 1.10 1.50 1.50 2.20 2.20
Head m 16 21 22 19 17 25 24 23 22 21
Refrigerant  Type   R22/R134A/R407C/R410A/R507/R404  
    Water tank Indicating Volume Liter 70 75 100 115 145 250 270 320 360 400
Safety protection   high and low pressure protection, overload protection, over temperature protection, phase sequence protection, etc.  
Dimensions (L*W*H)  Length mm 1150 1150 1200 1350 1400 1600 1950 2100 2200 2450
Width mm 560 560 850 850 850 1000 1250 1250 1250 1350
  High mm 1120 1120 1550 1550 1550 1600 1600 1600 1850 2050
 Total Weight KG 150 200' 285 350' 450 600 830 1050 1250 1350

 
Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, we can provide non-standard products according to customer requirements.

 

Company profile:

Winday Industrial is a professional R & D manufacturing and sales of industrial refrigeration equipment

and refrigeration system design, installation service company.

On behalf of product quality performance "efficient stability, progress energy efficiency."

Equipment manufacturing process to achieve excellence, strict control, strict examination;

Refrigeration program design to achieve repeated research, experiment, scrutiny, feasibility

studies and other processes,and strive to provide customers with an optimized cooling system integration solutions and equipment.
Chiller Units for Machining Coolant Systems Flush


Contact Way:
Chiller Units for Machining Coolant Systems Flush


Chiller Units For Machining Coolant Systems Flush
 

Our products as follow:

3kw ~ 3000kw/Outlet temperature:7ºC~ -85ºC/
Air cooled,water cooled,screw type,scroll type,heat pump chiller, modular chiller

 






Chiller Units for Machining Coolant Systems Flush









Chiller Units for Machining Coolant Systems Flush




The Details of the chiller:

1.The Temperature Range:7ºC to -85ºC.  

2.Cooling Capacity Range:

1RT to 1000RT

3.52kw to 3520kw

12010Btu to 12010240Btu

3027.2Kal to 3027200Kal

3. The Refrigerant: R22/R407c/R410a/R404a/R134a/R507c.
4.We can also produce the chiller according to your requirements.
Chiller Units for Machining Coolant Systems Flush






One Parameter of our water chiller:
Air-cooled chiller parameters(output tem 7ºC)

Model  UNIT WD-  
3AC/S 5AC/S 8AC/S 10AC/S 12AC/S 15AC/S 20AC/S 25AC/S 30AC/S 40AC/S
Cooling capacity Btu 30026 49133 87006 98948 111572 140233.2 188684 223145 280466 377367
RT 2.5 4.1 7.2 8.3 9.3 11.7 15.7 18.6 23.4 31.5
Kw 8.8 14.4 25.5 29.0 32.7 41.1 55.3 65.4 82.2 110.6
×10³Kcal/h 7.6 12.4 21.9 25.0 28.1 35.4 47.6 56.3 70.7 95.2
 Total Power KW 3.1 5.2 8.1 9.5 10.9 14.4 19.3 20.5 28.6 38.0
Total Current A 5.7 9.6 14.8 17.3 19.9 26.3 35.3 37.6 52.3 69.5
       Compressor  Qty set 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.00 2.00 2.00
Input power kw 2.6 4.3 7.0 7.9 8.9 12.4 16.6 17.9 24.9 33.3
 Operation Current A 4.6 7.6 12.4 14.0 15.9 22.1 29.6 31.8 44.3 59.2
Condenser Type Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger  
Fans Input power kw 0.19 0.42 0.38 0.84 0.84 0.84 1.14 1.14 1.50 2.52
Input
Current
 
A 0.50 0.85" 1.00 1.70" 1.70 1.70 3.00 3.00 3.84 5.10"
  Evaporator  Type   Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger  
  Freezing water Flow L/min 25 41 73 83 93 118 158 187 235 316
Water pipe connection mm 25" 25 32 32 32 40 40" 50 50 65"
Freezing Water Pump Type  High efficiency, low noise  
Input Power Kw 0.37 0.55 0.75 0.75 1.10 1.10 1.50 1.50 2.20 2.20
Head m 16 21 22 19 17 25 24 23 22 21
Refrigerant  Type   R22/R134A/R407C/R410A/R507/R404  
    Water tank Indicating Volume Liter 70 75 100 115 145 250 270 320 360 400
Safety protection   high and low pressure protection, overload protection, over temperature protection, phase sequence protection, etc.  
Dimensions (L*W*H)  Length mm 1150 1150 1200 1350 1400 1600 1950 2100 2200 2450
Width mm 560 560 850 850 850 1000 1250 1250 1250 1350
  High mm 1120 1120 1550 1550 1550 1600 1600 1600 1850 2050
 Total Weight KG 150 200' 285 350' 450 600 830 1050 1250 1350

 
Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, we can provide non-standard products according to customer requirements.

 

Company profile:

Winday Industrial is a professional R & D manufacturing and sales of industrial refrigeration equipment

and refrigeration system design, installation service company.

On behalf of product quality performance "efficient stability, progress energy efficiency."

Equipment manufacturing process to achieve excellence, strict control, strict examination;

Refrigeration program design to achieve repeated research, experiment, scrutiny, feasibility

studies and other processes,and strive to provide customers with an optimized cooling system integration solutions and equipment.
Chiller Units for Machining Coolant Systems Flush


Contact Way:
Chiller Units for Machining Coolant Systems Flush

Feature editing
1, the pulse bag type Dust Collector [1] uses the split room pulsing pulsate cleaning technology to overcome the shortcomings of the conventional pulse duster and the chamber back duster. It has strong cleaning ability, high dust removal efficiency, low emission concentration, small air leakage rate, less energy consumption, less steel consumption, less area, stable and reliable transportation and good economic benefit. It is suitable for purification and recovery of dust gas in metallurgy, building materials, cement, machinery, chemical industry, electric power and light industry.
2. Due to the use of parting air pulse to blow the ash and blowing ash, it can reach the goal of thoroughly cleaning ash once, so the period of dust removal is prolonged, the energy consumption of ash clearing is reduced, and the air pressure consumption can be greatly reduced. At the same time, the fatigue degree of the filter bag and the pulse valve is reduced correspondingly, thus multiplying the service life of the filter bag and the valve piece.
3. Maintenance and replacement bags can be divided into chambers under the condition of continuous system blower and normal operation of the system. The bag bag mouth adopts elastic expansion ring, which has good sealing performance and firmness and reliability. The filter bag keel is polygonal, which reduces the friction between the bag and the keel, prolongs the life of the bag, and is convenient for unloading the bag.
4. The upper bag is adopted. After changing the bag, the bag is put out and the dirty bag is put into the bottom ash hopper of the box. It is removed by Kong Chu and improved the operation condition of the bag changing.
5. The box is designed with tightness, good sealing performance, good sealing material for inspection door, leak detection with kerosene in production process, and low leakage rate.
6. Inlet and outlet air duct is compact and airflow resistance is small.

Pulse Bag Collector

Pulse Bag Collector,Bag Filtering Dust Precipitator,Dusty Air Cleaning Equipment ,High Temperature Pulse Bag Collector

Botou Youjian Environmental Protection Equipment Co. LTD. , http://www.btdustmachine.com